CVE-2024-44102 siemens telecontrol server basic: Deserialization of Untrusted Data

10.0 criticalEPSS 1.0%Fix available

Critical (10.0) in siemens telecontrol server basic. EPSS 1.0% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.

Severity

CVSS 4.0

10.0 critical
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

CVSS 3.1

10.0 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
EPSS
1.0% (unchanged from 1.0% a week ago; 1.0% 30 days ago) estimated probability of exploitation activity in the next 30 days; 64th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2024-11-15. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-502 Deserialization of Untrusted Data
OWASP Top 10
A08:2025 Software or Data Integrity Failures
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2024-44102 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-44102?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-44102?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-44102 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens PP TeleControl Server Basic 1000 to 5000 V3.1before V3.1.2.1
Siemens PP TeleControl Server Basic 256 to 1000 V3.1before V3.1.2.1
Siemens PP TeleControl Server Basic 32 to 64 V3.1before V3.1.2.1
Siemens PP TeleControl Server Basic 64 to 256 V3.1before V3.1.2.1
Siemens PP TeleControl Server Basic 8 to 32 V3.1before V3.1.2.1
Siemens TeleControl Server Basic 1000 V3.1before V3.1.2.1
Siemens TeleControl Server Basic 256 V3.1before V3.1.2.1
Siemens TeleControl Server Basic 32 V3.1before V3.1.2.1
Siemens TeleControl Server Basic 5000 V3.1before V3.1.2.1
Siemens TeleControl Server Basic 64 V3.1before V3.1.2.1
Siemens TeleControl Server Basic 8 V3.1before V3.1.2.1
Siemens TeleControl Server Basic Serv Upgrbefore V3.1.2.1
Siemens TeleControl Server Basic Upgr V3.1before V3.1.2.1

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-319-10Siemens TeleControl Server2024-11-12MultiplePP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) and 10 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-586 Object Injection Likelihood: Medium · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References