Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
1.5%(unchanged from 1.5% a week ago; 1.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 75th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2025-01-09. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-78Improper Neutralization of Special Elements used in an OS Command (OS Command Injection) CWE-434Unrestricted Upload of File with Dangerous Type
Show the promptExplain CVE-2024-43656 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-43656?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-43656?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-43656 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.