CVE-2024-32861 johnson controls software house c•cure 9000 installer: Incorrect Default Permissions

7.8 highEPSS 0.1%

High (7.8) in johnson controls software house c•cure 9000 installer. EPSS 0.1% estimated probability of exploitation activity in the next 30 days.

On this page
Under certain circumstances the impacted Software House C•CURE 9000 installer will utilize unnecessarily wide permissions.

Severity

CVSS 3.1

7.8 high
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS
0.1% (unchanged from 0.1% a week ago; 0.1% 30 days ago) estimated probability of exploitation activity in the next 30 days; 4th percentile. Scored 2026-11-23. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2024-07-16. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-276 Incorrect Default Permissions
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2024-32861 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-32861?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-32861?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-32861 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Johnson Controls Software House C•CURE 9000 Installerthrough 2.8

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-191-05Johnson Controls Inc. Software House C●CURE 9000 (Update B)2024-07-09Critical Manufacturing, Commercial Facilities, Government Facilities, Transportation Systems, EnergyJohnson Controls Inc. Software House C●CURE 9000 Site Server: <=2.80none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs Likelihood: High · Severity: High
  • CAPEC-81 Web Server Logs Tampering Likelihood: Medium · Severity: High
  • CAPEC-127 Directory Indexing Likelihood: High · Severity: Medium

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON