cve.bz

CVE-2024-29082 vonets: Improper Access Control

8.8 highEPSS 0.8%

High (8.8) in vonets. EPSS 0.8% estimated probability of exploitation activity in the next 30 days.

On this page
Improper access control vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication and factory reset the device via unprotected goform endpoints.

Severity

CVSS 4.0

8.8 high
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N

CVSS 3.1

8.6 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
EPSS
0.8% (unchanged from 0.8% a week ago; 0.8% 30 days ago) estimated probability of exploitation activity in the next 30 days; 57th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: partial, assessed 2024-08-09. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-284 Improper Access Control
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2024-29082 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-29082?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-29082?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-29082 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Vonets VAR1200-Hthrough 3.3.23.6.9
Vonets VAR1200-Lthrough 3.3.23.6.9
Vonets VAR600-Hthrough 3.3.23.6.9
Vonets VAP11ACthrough 3.3.23.6.9
Vonets VAP11G-500Sthrough 3.3.23.6.9
Vonets VBG1200through 3.3.23.6.9
Vonets VAP11S-5Gthrough 3.3.23.6.9
Vonets VAP11Sthrough 3.3.23.6.9
Vonets VAR11N-300through 3.3.23.6.9
Vonets VAP11G-300through 3.3.23.6.9
Vonets VAP11N-300through 3.3.23.6.9
Vonets VAP11Gthrough 3.3.23.6.9
Vonets VAP11G-500through 3.3.23.6.9
Vonets VGA-1000through 3.3.23.6.9

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-214-08Vonets WiFi Bridges2024-08-01CommunicationsVonets VAR1200-H: <=3.3.23.6.9, Vonets VAR1200-L: <=3.3.23.6.9, Vonets VAR600-H: <=3.3.23.6.9 and 11 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-284 (17).

References

Check your stackJSON