CVE-2024-22024 ivanti

8.3 highEPSS 95%Fix available

High (8.3) in ivanti. EPSS 95% estimated probability of exploitation activity in the next 30 days.

On this page
An XML external entity or XXE vulnerability in the SAML component of Ivanti Connect Secure (9.x, 22.x), Ivanti Policy Secure (9.x, 22.x) and ZTA gateways which allows an attacker to access certain restricted resources without authentication.

Severity

CVSS 3.1

8.3 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L
EPSS
95% (unchanged from 95% a week ago; 95% 30 days ago) estimated probability of exploitation activity in the next 30 days; 100th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: PoC · Automatable: yes · Technical impact: partial, assessed 2024-09-16. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-611 Improper Restriction of XML External Entity Reference
OWASP Top 10
A02:2025 Security Misconfiguration
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2024-22024 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-22024?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-22024?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-22024 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Ivanti ICSfrom 9.1R14.5 before 9.1R14.5
Ivanti ICSfrom 9.1R17.3 before 9.1R17.3
Ivanti ICSfrom 9.1R18.4 before 9.1R18.4
Ivanti ICSfrom 22.1R6.1 before 22.1R6.1
Ivanti ICSfrom 22.2R4.1 before 22.2R4.1
Ivanti ICSfrom 22.3R1.1 before 22.3R1.1
Ivanti ICSfrom 22.4R1.1 before 22.4R1.1
Ivanti ICSfrom 22.5R1.2 before 22.5R1.2
Ivanti ICSfrom 22.6R1.1 before 22.6R1.1
Ivanti ICSfrom 22.4R2.3 before 22.4R2.3
Ivanti ICSfrom 22.5R2.3 before 22.5R2.3
Ivanti ICSfrom 22.6R2.2 before 22.6R2.2
Ivant ICSfrom 9.1R15.3 before 9.1R15.3
Ivanti IPSfrom 9.1R18.4 before 9.1R18.4
Ivanti IPSfrom 9.1R17.3 before 9.1R17.3
Ivanti IPSfrom 22.5R1.2 before 22.5R1.2

Fixed in

ProductFixed in
Ivanti ICS9.1R14.4
Ivanti ICS9.1R15.2
Ivanti ICS9.1R16.2
Ivanti ICS9.1R17.2
Ivanti ICS9.1R18.3
Ivanti ICS22.1R6.1
Ivanti ICS22.2R4.1
Ivanti ICS22.3R1
Ivanti ICS22.4R1.1
Ivanti ICS22.5R1.1
Ivanti ICS22.6R1.1
Ivanti ICS22.4R2.2
Ivanti ICS22.5R2.2
Ivanti ICS22.6R2.2
Ivanti IPS9.1R18.2
Ivanti IPS9.1R17.2
Ivanti IPS22.5R1.1

Detection rules

Ways to detect this CVE, not exploit code: the nuclei template that checks a system for it, and the Suricata and Snort rules that name it. A rule set may ship a rule turned off, so check yours by its sid.

  • Nuclei template Ivanti Connect Secure - XXE
  • Emerging Threats Open ET WEB_SPECIFIC_APPS Ivanti Connect Secure XXE Attempt (CVE-2024-22024) sid 2050784

Attack patterns (CAPEC)

  • CAPEC-221 Data Serialization External Entities Blowup

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON