cve.bz

CVE-2024-10697 tenda ac6 firmware: Injection

5.3 mediumExploit referenceEPSS 26%

Medium (5.3) in tenda ac6 firmware. EPSS 26% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac of the component API Endpoint. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Severity

CVSS 4.0

5.3 medium
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
26% (unchanged from 26% a week ago; 26% 30 days ago) estimated probability of exploitation activity in the next 30 days; 98th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: PoC · Automatable: no · Technical impact: partial, assessed 2024-11-05. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (Injection)
CWE-77 Improper Neutralization of Special Elements used in a Command
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2024-10697 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2024-10697?via=ask-ai-copy and https://cve.bz/cve/CVE-2024-10697?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2024-10697 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
tenda:ac6_firmware15.03.05.19

Attack patterns (CAPEC)

  • CAPEC-15 Command Delimiters Likelihood: High · Severity: High
  • CAPEC-40 Manipulating Writeable Terminal Devices Likelihood: High · Severity: Very High
  • CAPEC-43 Exploiting Multiple Input Interpretation Layers Likelihood: Medium · Severity: High
  • CAPEC-75 Manipulating Writeable Configuration Files Likelihood: High · Severity: Very High
  • CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
  • CAPEC-136 LDAP Injection Likelihood: High · Severity: High
  • CAPEC-183 IMAP/SMTP Command Injection Severity: Medium
  • CAPEC-248 Command Injection Likelihood: Medium · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-74 (37).

References

Check your stackJSON