cve.bz

CVE-2023-6408 schneider-electric

8.1 highEPSS 0.3%

High (8.1) in schneider-electric. EPSS 0.3% estimated probability of exploitation activity in the next 30 days.

On this page
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack.

Severity

CVSS 3.1

8.1 high
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.3% (unchanged from 0.3% a week ago; 0.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 25th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2024-07-17. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Published
Modified
NVD analysis
Analyzed
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2023-6408 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2023-6408?via=ask-ai-copy and https://cve.bz/cve/CVE-2023-6408?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2023-6408 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:modicon_m340_bmxp341000_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp341000h_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp342000_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp342010_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp3420102_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp3420102cl_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp342020_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp342020h_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp342030_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp3420302_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp3420302cl_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp3420302h_firmwarebefore 3.60
schneider-electric:modicon_m340_bmxp342030h_firmwarebefore 3.60
schneider-electric:modicon_m580_bmep581020_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep581020h_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep582020_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep582020h_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep582040_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep582040h_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep582040s_firmwarebefore 4.21
schneider-electric:modicon_m580_bmep583020_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep583040_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep584040_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep584020_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep584040s_firmwarebefore 4.21
schneider-electric:modicon_m580_bmep585040_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep585040c_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep586040_firmwarebefore 4.20
schneider-electric:modicon_m580_bmep586040c_firmwarebefore 4.20
schneider-electric:modicon_m580_bmeh582040_firmwarebefore 4.20
schneider-electric:modicon_m580_bmeh582040c_firmwarebefore 4.20
schneider-electric:modicon_m580_bmeh584040_firmwarebefore 4.20
schneider-electric:modicon_m580_bmeh582040s_firmwarebefore 4.21
schneider-electric:modicon_m580_bmeh584040c_firmwarebefore 4.20
schneider-electric:modicon_m580_bmeh584040s_firmwarebefore 4.21
schneider-electric:modicon_m580_bmeh586040_firmwarebefore 4.20
schneider-electric:modicon_m580_bmeh586040c_firmwarebefore 4.20
schneider-electric:modicon_m580_bmeh586040s_firmwarebefore 4.21
schneider-electric:ecostruxure_control_expertbefore 16.0
schneider-electric:ecostruxure_process_expertbefore 2023

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-331-03Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340, M580 and M580 Safety PLCs2024-02-13Critical ManufacturingModicon M340 CPU (part numbers BMXP34*) Versions prior to sv3.60, Modicon M580 CPU (part numbers BMEP* and BMEH* excluding M580 CPU Safety) Versions prior to sv4.20, Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) Versions prior to SV4.21 and 4 moreModicon M340 CPU (part numbers BMXP34*) SV3.60, Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) SV4.20, EcoStruxure Control Expert Version 16.0 and 3 more

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

References

Check your stackJSON