cve.bz

CVE-2023-46282 siemens: Cross-site Scripting

6.1 mediumEPSS 0.5%Fix available

Medium (6.1) in siemens. EPSS 0.5% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.

Severity

CVSS 3.1

6.1 medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
EPSS
0.5% (unchanged from 0.5% a week ago; 0.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 43rd percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2023-46282 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2023-46282?via=ask-ai-copy and https://cve.bz/cve/CVE-2023-46282?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2023-46282 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens Opcenter Execution Foundationbefore V2407
Siemens Opcenter Qualitybefore V2312
Siemens SIMATIC PCS neobefore V4.1
Siemens SINEC NMSbefore V2.0 SP1
Siemens Totally Integrated Automation Portal (TIA Portal) V14all versions
Siemens Totally Integrated Automation Portal (TIA Portal) V15.1all versions
Siemens Totally Integrated Automation Portal (TIA Portal) V16all versions
Siemens Totally Integrated Automation Portal (TIA Portal) V17before V17 Update 8
Siemens Totally Integrated Automation Portal (TIA Portal) V18before V18 Update 3

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-23-348-03Siemens User Management Component (UMC)2023-12-12Critical ManufacturingOpcenter Execution Foundation, Opcenter Quality, SIMATIC PCS neo and 6 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-63 Cross-Site Scripting (XSS) Likelihood: High · Severity: Very High
  • CAPEC-85 AJAX Footprinting Likelihood: High · Severity: Low
  • CAPEC-209 XSS Using MIME Type Mismatch Severity: Medium
  • CAPEC-588 DOM-Based XSS Likelihood: High · Severity: Very High
  • CAPEC-591 Reflected XSS Likelihood: High · Severity: Very High
  • CAPEC-592 Stored XSS Likelihood: High · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON