cve.bz

CVE-2023-4542 dlink dar-8000-10 firmware: OS Command Injection

9.8 criticalExploit referenceEPSS 85%

Critical (9.8) in dlink dar-8000-10 firmware. EPSS 85% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
85% (unchanged from 85% a week ago; 85% 30 days ago) estimated probability of exploitation activity in the next 30 days; 100th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-78 Improper Neutralization of Special Elements used in an OS Command (OS Command Injection)
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2023-4542 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2023-4542?via=ask-ai-copy and https://cve.bz/cve/CVE-2023-4542?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2023-4542 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
dlink:dar-8000-10_firmwarethrough 2023-08-09

Detection rules

Ways to detect this CVE, not exploit code: the nuclei template that checks a system for it, and the Suricata and Snort rules that name it. A rule set may ship a rule turned off, so check yours by its sid.

Attack patterns (CAPEC)

  • CAPEC-6 Argument Injection Likelihood: High · Severity: High
  • CAPEC-15 Command Delimiters Likelihood: High · Severity: High
  • CAPEC-43 Exploiting Multiple Input Interpretation Layers Likelihood: Medium · Severity: High
  • CAPEC-88 OS Command Injection Likelihood: High · Severity: High
  • CAPEC-108 Command Line Execution through SQL Injection Likelihood: Low · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON