CVE-2023-44321 siemens: Uncontrolled Resource Consumption

5.1 mediumEPSS 1.2%

Medium (5.1) in siemens. EPSS 1.2% estimated probability of exploitation activity in the next 30 days.

On this page
Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.

Severity

CVSS 4.0

5.1 medium
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N

CVSS 3.1

6.5 medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
EPSS
1.2% (unchanged from 1.2% a week ago; 1.0% 30 days ago) estimated probability of exploitation activity in the next 30 days; 70th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2024-01-06. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-400 Uncontrolled Resource Consumption
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2023-44321 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2023-44321?via=ask-ai-copy and https://cve.bz/cve/CVE-2023-44321?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2023-44321 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens RUGGEDCOM RM1224 LTE(4G) EUbefore V8.1
Siemens RUGGEDCOM RM1224 LTE(4G) NAMbefore V8.1
Siemens SCALANCE M804PBbefore V8.1
Siemens SCALANCE M812-1 ADSL-Router familybefore V8.1
Siemens SCALANCE M816-1 ADSL-Router familybefore V8.1
Siemens SCALANCE M826-2 SHDSL-Routerbefore V8.1
Siemens SCALANCE M874-2before V8.1
Siemens SCALANCE M874-3before V8.1
Siemens SCALANCE M874-3 3G-Router (CN)before V8.1
Siemens SCALANCE M876-3before V8.1
Siemens SCALANCE M876-3 (ROK)before V8.1
Siemens SCALANCE M876-4before V8.1
Siemens SCALANCE M876-4 (EU)before V8.1
Siemens SCALANCE M876-4 (NAM)before V8.1
Siemens SCALANCE MUM853-1 (A1)before V8.1
Siemens SCALANCE MUM853-1 (B1)before V8.1
Siemens SCALANCE MUM853-1 (EU)before V8.1
Siemens SCALANCE MUM856-1 (A1)before V8.1
Siemens SCALANCE MUM856-1 (B1)before V8.1
Siemens SCALANCE MUM856-1 (CN)before V8.1
Siemens SCALANCE MUM856-1 (EU)before V8.1
Siemens SCALANCE MUM856-1 (RoW)before V8.1
Siemens SCALANCE S615 EEC LAN-Routerbefore V8.1
Siemens SCALANCE S615 LAN-Routerbefore V8.1
Siemens SCALANCE XB205-3 (SC, PN)before V4.6
Siemens SCALANCE XB205-3 (ST, E/IP)before V4.6
Siemens SCALANCE XB205-3 (ST, PN)before V4.6
Siemens SCALANCE XB205-3LD (SC, E/IP)before V4.6
Siemens SCALANCE XB205-3LD (SC, PN)before V4.6
Siemens SCALANCE XB206-2 (SC)before V4.6
Siemens SCALANCE XB206-2 (ST/BFOC)before V4.6
Siemens SCALANCE XB206-2 LDbefore V4.6
Siemens SCALANCE XB206-2 SCbefore V4.6
Siemens SCALANCE XB206-2 STbefore V4.6
Siemens SCALANCE XB206-2LDbefore V4.6
Siemens SCALANCE XB208 (E/IP)before V4.6
Siemens SCALANCE XB208 (PN)before V4.6
Siemens SCALANCE XB213-3 (SC, E/IP)before V4.6
Siemens SCALANCE XB213-3 (SC, PN)before V4.6
Siemens SCALANCE XB213-3 (ST, E/IP)before V4.6
Siemens SCALANCE XB213-3 (ST, PN)before V4.6
Siemens SCALANCE XB213-3LD (SC, E/IP)before V4.6
Siemens SCALANCE XB213-3LD (SC, PN)before V4.6
Siemens SCALANCE XB216 (E/IP)before V4.6
Siemens SCALANCE XB216 (PN)before V4.6
Siemens SCALANCE XC206-2 (SC)before V4.6
Siemens SCALANCE XC206-2 (ST/BFOC)before V4.6
Siemens SCALANCE XC206-2G PoEbefore V4.6
Siemens SCALANCE XC206-2G PoE (54 V DC)before V4.6
Siemens SCALANCE XC206-2G PoE EEC (54 V DC)before V4.6
Siemens SCALANCE XC206-2SFPbefore V4.6
Siemens SCALANCE XC206-2SFP EECbefore V4.6
Siemens SCALANCE XC206-2SFP Gbefore V4.6
Siemens SCALANCE XC206-2SFP G (EIP DEF.)before V4.6
Siemens SCALANCE XC206-2SFP G EECbefore V4.6
Siemens SCALANCE XC208before V4.6
Siemens SCALANCE XC208EECbefore V4.6
Siemens SCALANCE XC208Gbefore V4.6
Siemens SCALANCE XC208G (EIP def.)before V4.6
Siemens SCALANCE XC208G EECbefore V4.6
Siemens SCALANCE XC208G PoEbefore V4.6
Siemens SCALANCE XC208G PoE (54 V DC)before V4.6
Siemens SCALANCE XC216before V4.6
Siemens SCALANCE XC216-3G PoEbefore V4.6
Siemens SCALANCE XC216-3G PoE (54 V DC)before V4.6
Siemens SCALANCE XC216-4Cbefore V4.6
Siemens SCALANCE XC216-4C Gbefore V4.6
Siemens SCALANCE XC216-4C G (EIP Def.)before V4.6
Siemens SCALANCE XC216-4C G EECbefore V4.6
Siemens SCALANCE XC216EECbefore V4.6
Siemens SCALANCE XC224before V4.6
Siemens SCALANCE XC224-4C Gbefore V4.6
Siemens SCALANCE XC224-4C G (EIP Def.)before V4.6
Siemens SCALANCE XC224-4C G EECbefore V4.6
Siemens SCALANCE XF204before V4.6
Siemens SCALANCE XF204 DNAbefore V4.6
Siemens SCALANCE XF204-2BAbefore V4.6
Siemens SCALANCE XF204-2BA DNAbefore V4.6
Siemens SCALANCE XF204Gbefore V4.6
Siemens SCALANCE XP208before V4.6
Siemens SCALANCE XP208 (Ethernet/IP)before V4.6
Siemens SCALANCE XP208EECbefore V4.6
Siemens SCALANCE XP208Gbefore V4.6
Siemens SCALANCE XP208G EECbefore V4.6
Siemens SCALANCE XP208G PoE EECbefore V4.6
Siemens SCALANCE XP208G PPbefore V4.6
Siemens SCALANCE XP208PoE EECbefore V4.6
Siemens SCALANCE XP216before V4.6
Siemens SCALANCE XP216 (Ethernet/IP)before V4.6
Siemens SCALANCE XP216 (V2)before V4.6
Siemens SCALANCE XP216EECbefore V4.6
Siemens SCALANCE XP216EEC (V2)before V4.6
Siemens SCALANCE XP216Gbefore V4.6
Siemens SCALANCE XP216G EECbefore V4.6
Siemens SCALANCE XP216G PoE EECbefore V4.6
Siemens SCALANCE XP216POE EECbefore V4.6
Siemens SCALANCE XP216PoE EEC (V2)before V4.6
Siemens SCALANCE XR324WG (24 x FE, AC 230V)before V4.6
Siemens SCALANCE XR324WG (24 X FE, DC 24V)before V4.6
Siemens SCALANCE XR326-2C PoE WGbefore V4.6
Siemens SCALANCE XR326-2C PoE WG (without UL)before V4.6
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)before V4.6
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)before V4.6
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)before V4.6
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V)before V4.6
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V)before V4.6
Siemens SIPLUS NET SCALANCE XC206-2before V4.6
Siemens SIPLUS NET SCALANCE XC206-2SFPbefore V4.6
Siemens SIPLUS NET SCALANCE XC208before V4.6
Siemens SIPLUS NET SCALANCE XC216-4Cbefore V4.6

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-228-01Siemens SCALANCE M-800, RUGGEDCOM RM12242024-08-13MultipleRUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2), SCALANCE M804PB (6GK5804-0AP00-2AA2) and 21 morenone listed
ICSA-24-074-08Siemens SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family2024-03-12Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and FacilitiesSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2), SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2), SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2) and 47 morenone listed
ICSA-24-046-09Siemens SCALANCE SC-600 Family2024-02-13MultipleSCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) and 3 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-147 XML Ping of the Death Likelihood: Low · Severity: Medium
  • CAPEC-227 Sustained Client Engagement
  • CAPEC-492 Regular Expression Exponential Blowup

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON