cve.bz

CVE-2023-32736 siemens: Deserialization of Untrusted Data

7.0 highEPSS 0.2%

High (7.0) in siemens. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

Severity

CVSS 4.0

7.0 high
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS 3.1

7.3 high
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
EPSS
0.2% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 12th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2024-12-02. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-502 Deserialization of Untrusted Data
OWASP Top 10
A08:2025 Software or Data Integrity Failures
Published
Modified
NVD analysis
Deferred: the NVD does not plan to analyze it
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2023-32736 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2023-32736?via=ask-ai-copy and https://cve.bz/cve/CVE-2023-32736?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2023-32736 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens SIMATIC S7-PLCSIM V16all versions
Siemens SIMATIC S7-PLCSIM V17all versions
Siemens SIMATIC STEP 7 Safety V16all versions
Siemens SIMATIC STEP 7 Safety V17before V17 Update 8
Siemens SIMATIC STEP 7 Safety V18before V18 Update 5
Siemens SIMATIC STEP 7 V16all versions
Siemens SIMATIC STEP 7 V17before V17 Update 8
Siemens SIMATIC STEP 7 V18before V18 Update 5
Siemens SIMATIC WinCC Unified V16all versions
Siemens SIMATIC WinCC Unified V17before V17 Update 8
Siemens SIMATIC WinCC Unified V18before V18 SP5
Siemens SIMATIC WinCC V16all versions
Siemens SIMATIC WinCC V17before V17 Update 8
Siemens SIMATIC WinCC V18before V18 SP5
Siemens SIMOCODE ES V16all versions
Siemens SIMOCODE ES V17before V17 Update 8
Siemens SIMOCODE ES V18all versions
Siemens SIMOTION SCOUT TIA V5.4 SP1all versions
Siemens SIMOTION SCOUT TIA V5.4 SP3all versions
Siemens SIMOTION SCOUT TIA V5.5 SP1all versions
Siemens SINAMICS Startdrive V16all versions
Siemens SINAMICS Startdrive V17all versions
Siemens SINAMICS Startdrive V18all versions
Siemens SIRIUS Safety ES V17 (TIA Portal)before V17 Update 8
Siemens SIRIUS Safety ES V18 (TIA Portal)all versions
Siemens SIRIUS Soft Starter ES V17 (TIA Portal)before V17 Update 8
Siemens SIRIUS Soft Starter ES V18 (TIA Portal)all versions
Siemens TIA Portal Cloud V16all versions
Siemens TIA Portal Cloud V17before V4.6.0.1
Siemens TIA Portal Cloud V18before V4.6.1.0

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-24-319-07Siemens Engineering Platforms2024-11-12Critical ManufacturingSIMATIC S7-PLCSIM V16, SIMATIC S7-PLCSIM V17, SIMATIC STEP 7 Safety V16 and 27 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-586 Object Injection Likelihood: Medium · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON