cve.bz

CVE-2023-28343 apsystems energy communication unit firmware: OS Command Injection

9.8 criticalExploitEPSS 85%

Critical (9.8) in apsystems energy communication unit firmware. EPSS 85% estimated probability of exploitation activity in the next 30 days.

On this page
OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/set_timezone timezone parameter, because of set_timezone in models/management_model.php.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
85% (unchanged from 85% a week ago; 85% 30 days ago) estimated probability of exploitation activity in the next 30 days; 100th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2025-02-27. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-78 Improper Neutralization of Special Elements used in an OS Command (OS Command Injection)
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2023-28343 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2023-28343?via=ask-ai-copy and https://cve.bz/cve/CVE-2023-28343?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2023-28343 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
apsystems:energy_communication_unit_firmwarec1.2.5

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-23-213-01APSystems Altenergy Power Control2023-08-01EnergyAltenergy Power Control Software: C1.2.5none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Public exploits

Detection rules

Ways to detect this CVE, not exploit code: the nuclei template that checks a system for it, and the Suricata and Snort rules that name it. A rule set may ship a rule turned off, so check yours by its sid.

Attack patterns (CAPEC)

  • CAPEC-6 Argument Injection Likelihood: High · Severity: High
  • CAPEC-15 Command Delimiters Likelihood: High · Severity: High
  • CAPEC-43 Exploiting Multiple Input Interpretation Layers Likelihood: Medium · Severity: High
  • CAPEC-88 OS Command Injection Likelihood: High · Severity: High
  • CAPEC-108 Command Line Execution through SQL Injection Likelihood: Low · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON