CVE-2023-26293
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.
- CVSS 3.1
- 7.3
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L - EPSS
- 0.2% chance of exploitation in the next 30 days; higher than 16% of CVEs (scores of 2026-10-25)
- CWEs
- CWE-20, CWE-22
- Published
- Modified
- Record from
- the NVD, synced
Affected
- siemens:tia_portal