cve.bz

CVE-2023-0863 abb: Improper Authentication

8.8 highEPSS 0.3%

High (8.8) in abb. EPSS 0.3% estimated probability of exploitation activity in the next 30 days.

On this page
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.

Severity

CVSS 3.1

8.8 high
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.3% (unchanged from 0.3% a week ago; 0.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 29th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2025-01-22. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-287 Improper Authentication
OWASP Top 10
A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2023-0863 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2023-0863?via=ask-ai-copy and https://cve.bz/cve/CVE-2023-0863?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2023-0863 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
ABB Terra AC wallbox (UL40/80A)from 1.0;0 through 1.5.5
ABB Terra AC wallbox (UL32A)from 1.0;0 through 1.6.5
ABB Terra AC wallbox (CE) (Terra AC MID)from 1.0;0 through 1.6.5
ABB Terra AC wallbox (CE) Terra AC Juno CEfrom 1.0;0 through 1.6.5
ABB Terra AC wallbox (CE) Terra AC PTBfrom 1.0;0 through 1.5.25
ABB Terra AC wallbox (CE) Symbiosisfrom 1.0;0 through 1.2.7
ABB Terra AC wallbox (JP)from 1.0;0 through 1.6.5

Attack patterns (CAPEC)

  • CAPEC-22 Exploiting Trust in Client Likelihood: High · Severity: High
  • CAPEC-57 Utilizing REST's Trust in the System Resource to Obtain Sensitive Data Likelihood: Medium · Severity: Very High
  • CAPEC-94 Adversary in the Middle (AiTM) Likelihood: High · Severity: Very High
  • CAPEC-114 Authentication Abuse Severity: Medium
  • CAPEC-115 Authentication Bypass Severity: Medium
  • CAPEC-151 Identity Spoofing Likelihood: Medium · Severity: Medium
  • CAPEC-194 Fake the Source of Data Severity: Medium
  • CAPEC-593 Session Hijacking Likelihood: High · Severity: Very High
  • CAPEC-633 Token Impersonation Severity: Medium
  • CAPEC-650 Upload a Web Shell to a Web Server Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON