cve.bz

CVE-2022-47374 siemens: Uncontrolled Recursion

7.5 highEPSS 0.7%

High (7.5) in siemens. EPSS 0.7% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly. This could allow an attacker to exhaust system resources and create a denial of service condition for the device.

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
0.7% (unchanged from 0.7% a week ago; 0.7% 30 days ago) estimated probability of exploitation activity in the next 30 days; 55th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: partial, assessed 2023-12-23. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-674 Uncontrolled Recursion
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2022-47374 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2022-47374?via=ask-ai-copy and https://cve.bz/cve/CVE-2022-47374?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2022-47374 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:sinamics_s120_firmware4.7
siemens:sinamics_s120_firmware4.8
siemens:sinamics_s120_firmware4.9
siemens:sinamics_s120_firmware5.0
siemens:sinamics_s120_firmware5.1:sp1
siemens:sinamics_s120_firmware5.1:sp1_hotfix1
siemens:sinamics_s120_firmware5.1:sp1_hotfix13
siemens:sinamics_s120_firmware5.2
siemens:sinamics_s120_firmware5.2:hotfix1
siemens:sinamics_s120_firmware5.2:hotfix11
siemens:sinamics_s120_firmware5.2:hotfix7
siemens:sinamics_s120_firmware5.2:sp3
siemens:sinamics_s120_firmware5.2:sp3_hotfix1
siemens:sinamics_s120_firmware5.2:sp3_hotfix13
siemens:sinamics_s120_firmware5.2:sp3_hotfix6
siemens:sinamics_s120_firmware5.2:sp3_hotfix9

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-23-348-05Siemens SIMATIC and SIPLUS Products2023-12-12MultipleSIMATIC PC-Station Plus, SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0), SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0) and 6 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-230 Serialized Data with Nested Payloads Likelihood: Medium · Severity: High
  • CAPEC-231 Oversized Serialized Data Payloads Likelihood: Medium · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON