cve.bz

CVE-2022-46144 siemens

7.1 highEPSS 1.0%Fix available

High (7.1) in siemens. EPSS 1.0% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.

Severity

CVSS 4.0

7.1 high
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

CVSS 3.1

6.5 medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
EPSS
1.0% (unchanged from 0.9% a week ago; 0.9% 30 days ago) estimated probability of exploitation activity in the next 30 days; 63rd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2025-04-18. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-664 Improper Control of a Resource Through its Lifetime
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2022-46144 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2022-46144?via=ask-ai-copy and https://cve.bz/cve/CVE-2022-46144?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2022-46144 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens SCALANCE SC622-2Cbefore V2.3
Siemens SCALANCE SC622-2Cfrom V2.3 before V3.0
Siemens SCALANCE SC626-2Cbefore V2.3
Siemens SCALANCE SC626-2Cfrom V2.3 before V3.0
Siemens SCALANCE SC632-2Cbefore V2.3
Siemens SCALANCE SC632-2Cfrom V2.3 before V3.0
Siemens SCALANCE SC636-2Cbefore V2.3
Siemens SCALANCE SC636-2Cfrom V2.3 before V3.0
Siemens SCALANCE SC642-2Cbefore V2.3
Siemens SCALANCE SC642-2Cfrom V2.3 before V3.0
Siemens SCALANCE SC646-2Cbefore V2.3
Siemens SCALANCE SC646-2Cfrom V2.3 before V3.0
Siemens SCALANCE WAM763-1before V2.0.0
Siemens SCALANCE WAM766-1before V2.0.0
Siemens SCALANCE WAM766-1 (US)before V2.0.0
Siemens SCALANCE WAM766-1 EECbefore V2.0.0
Siemens SCALANCE WAM766-1 EEC (US)before V2.0.0
Siemens SCALANCE WUM763-1before V2.0.0
Siemens SCALANCE WUM766-1before V2.0.0
Siemens SCALANCE WUM766-1 (USA)before V2.0.0

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-22-349-04Siemens SCALANCE Products2022-12-13Critical ManufacturingSCALANCE SC622-2C (6GK5622-2GS00-2AC2), SCALANCE SC626-2C (6GK5626-2GS00-2AC2), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) and 12 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-21 Exploitation of Trusted Identifiers Likelihood: High · Severity: High
  • CAPEC-60 Reusing Session IDs (aka Session Replay) Likelihood: High · Severity: High
  • CAPEC-61 Session Fixation Likelihood: Medium · Severity: High
  • CAPEC-62 Cross Site Request Forgery Likelihood: High · Severity: Very High
  • CAPEC-196 Session Credential Falsification through Forging Likelihood: Medium · Severity: Medium

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON