CVE-2022-4046 codesys

8.8 highEPSS 0.9%

High (8.8) in codesys. EPSS 0.9% estimated probability of exploitation activity in the next 30 days.

On this page
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.

Severity

CVSS 3.1

8.8 high
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS
0.9% (unchanged from 0.9% a week ago; 0.9% 30 days ago) estimated probability of exploitation activity in the next 30 days; 60th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2026-05-29. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2022-4046 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2022-4046?via=ask-ai-copy and https://cve.bz/cve/CVE-2022-4046?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2022-4046 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
CODESYS Control for BeagleBone SLall
CODESYS Control for emPC-A/iMX6 SLall
CODESYS Control for IOT2000 SLall
CODESYS Control for Linux SLall
CODESYS Control for PFC100 SLall
CODESYS Control for PFC200 SLall
CODESYS Control for PLCnext SLall
CODESYS Control for Raspberry Pi SLall
CODESYS Control for WAGO Touch Panels 600 SLall
CODESYS Control RTE (for Beckhoff CX) SLall
CODESYS Control RTE (SL)all
CODESYS Control Runtime System Toolkitall
CODESYS Control Win (SL)all
CODESYS HMI (SL)all

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-26-076-01CODESYS in Festo Automation Suite2026-02-26Critical ManufacturingFesto Automation Suite <2.8.0.138 installed with CODESYS Development System 3.0, Festo Automation Suite <2.8.0.138 installed with CODESYS Development System 3.5.16.10, Festo Automation Suite 2.8.0.137 installed with CODESYS Development System 3.0 and 1 moreCODESYS Development System 3.5.21.20 external component of Festo Automation Suite 2.8.0.138
ICSA-25-112-04ABB MV Drives2025-04-10Critical ManufacturingACS6080 Firmware Version LAAAA 2.10.0 to LAAAB 5.06.1, ACS5000 Firmware Version LAAAB 4.03.0 to LAAAB 5.06.1, ACS6000 Firmware Version LAAAA 2.10.0 to LAAAB 5.06.1ACS6080 Firmware Version LAAAB 5.07, ACS5000 Firmware Version LAAAB 5.07, ACS6000 Firmware Version LAAAB 5.07
ICSA-25-093-03ABB ACS880 Drives Containing CODESYS RTS2025-03-26Critical ManufacturingACS880 Primary Control Program AINLX < v3.47, ACS880 Primary Control Program YINLX < v1.30, ACS880 IGBT Supply Control Program AISLX < v3.43 and 5 moreACS880 Primary Control Program AINLX >=v3.47, ACS880 Primary Control Program YINLX >= v1.30, ACS880 IGBT Supply Control Program AISLX >= v3.43 and 3 more
ICSA-25-093-04ABB Low Voltage DC Drives and Power Controllers CODESYS RTS2025-03-26Critical ManufacturingDCS880 memory unit incl. ABB Drive Application Builder license (IEC 61131-3), DCS880 memory unit incl. DEMag, DCS880 memory unit incl. DCC and 2 morenone listed
ICSA-26-020-02Schneider Electric devices using CODESYS Runtime2023-07-11Commercial Facilities, Critical Manufacturing, EnergySchneider Electric HMISCU Controller All versions prior to v6.3.1, Schneider Electric Modicon Controller LMC078 All Versions, Schneider Electric Modicon Controller M241 All versions prior to v5.2.11.18 and 14 moreSchneider Electric HMISCU Controller 6.3.1, Schneider Electric Modicon Controller M241 5.2.11.18, Schneider Electric Modicon Controller M251 5.2.11.18 and 9 more