cve.bz

CVE-2022-40202 deltaww infrasuite device master

9.8 criticalEPSS 1.6%Fix available

Critical (9.8) in deltaww infrasuite device master. EPSS 1.6% estimated probability of exploitation activity in the next 30 days.

On this page
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
1.6% (unchanged from 1.6% a week ago; 1.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 77th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2025-04-16. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-306 Missing Authentication for Critical Functionality
OWASP Top 10
A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2022-40202 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2022-40202?via=ask-ai-copy and https://cve.bz/cve/CVE-2022-40202?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2022-40202 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Delta Electronics InfraSuite Device Masterthrough 00.00.01a

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-22-298-07Delta Electronics InfraSuite Device Master2022-10-25EnergyInfraSuite Device Master - Version 00.00.01a and prior, InfraSuite Device Master: Version 1.0.3 and priornone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-12 Choosing Message Identifier Likelihood: High · Severity: High
  • CAPEC-36 Using Unpublished Interfaces or Functionality Likelihood: Medium · Severity: High
  • CAPEC-62 Cross Site Request Forgery Likelihood: High · Severity: Very High
  • CAPEC-166 Force the System to Reset Values Severity: Medium
  • CAPEC-216 Communication Channel Manipulation

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON