cve.bz

CVE-2022-26507 Out-of-bounds Write

9.8 criticalEPSS 2.4%

Critical (9.8). EPSS 2.4% estimated probability of exploitation activity in the next 30 days.

On this page
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
2.4% (unchanged from 2.4% a week ago; 2.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 85th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-787 Out-of-bounds Write
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2022-26507 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2022-26507?via=ask-ai-copy and https://cve.bz/cve/CVE-2022-26507?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2022-26507 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
att:xmill0.7
schneider-electric:ecostruxure_control_expertbefore 15.1
schneider-electric:ecostruxure_control_expert15.1
schneider-electric:ecostruxure_process_expertbefore 2021

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-22-223-03Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x702022-08-11EcoStruxure Control Expert: All versions (including former Unity Pro) prior to V15.1 HF001, EcoStruxure Process Expert: All versions (including former HDCS) prior to V2021, SCADAPack RemoteConnect for x70: All versions prior to R2.7.3none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

References

Check your stackJSON