High (7.8) in rockwellautomation. EPSS 11% chance of exploitation in the next 30 days.

Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited

Severity

CVSS 3.1

7.8 high
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS
11% chance of exploitation in the next 30 days; higher than 95% of CVEs (scores of 2026-10-31)
CWE
CWE-502