cve.bz

CVE-2021-46152 siemens simcenter femap: Type Confusion

7.8 highEPSS 1.6%

High (7.8) in siemens simcenter femap. EPSS 1.6% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a type confusion vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14643, ZDI-CAN-14644, ZDI-CAN-14755, ZDI-CAN-15183)

Severity

CVSS 3.1

7.8 high
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS
1.6% (unchanged from 1.6% a week ago; 1.6% 30 days ago) estimated probability of exploitation activity in the next 30 days; 76th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-843 Access of Resource Using Incompatible Type (Type Confusion)
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-46152 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-46152?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-46152?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-46152 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:simcenter_femap2020.2
siemens:simcenter_femap2020.2:maintenance_pack1
siemens:simcenter_femap2020.2:maintenance_pack2
siemens:simcenter_femap2020.2:maintenance_pack3
siemens:simcenter_femap2021.1
siemens:simcenter_femap2021.1:maintenance_pack1
siemens:simcenter_femap2021.1:maintenance_pack2
siemens:simcenter_femap2021.1:maintenance_pack3

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-22-041-03Siemens Simcenter Femap2022-02-08MultipleSimcenter Femap V2020.2, Simcenter Femap V2021.1none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

References

Check your stackJSON