On this page
A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.8), RUGGEDCOM i801 (All versions < V4.3.8), RUGGEDCOM i802 (All versions < V4.3.8), RUGGEDCOM i803 (All versions < V4.3.8), RUGGEDCOM M2100 (All versions < V4.3.8), RUGGEDCOM M2200 (All versions < V4.3.8), RUGGEDCOM M969 (All versions < V4.3.8), RUGGEDCOM RMC30 (All versions < V4.3.8), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.8), RUGGEDCOM RMC8388 V5.X (All versions < V5.7.0), RUGGEDCOM RP110 (All versions < V4.3.8), RUGGEDCOM RS1600 (All versions < V4.3.8), RUGGEDCOM RS1600F (All versions < V4.3.8), RUGGEDCOM RS1600T (All versions < V4.3.8), RUGGEDCOM RS400 (All versions < V4.3.8), RUGGEDCOM RS401 (All versions < V4.3.8), RUGGEDCOM RS416 (All versions < V4.3.8), RUGGEDCOM RS416P (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.7.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416v2 V5.X (All versions < V5.7.0), RUGGEDCOM RS8000 (All versions < V4.3.8), RUGGEDCOM RS8000A (All versions < V4.3.8), RUGGEDCOM RS8000H (All versions < V4.3.8), RUGGEDCOM RS8000T (All versions < V4.3.8), RUGGEDCOM RS900 (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900G (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900GP (All versions < V4.3.8), RUGGEDCOM RS900L (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-XX (All versions < V4.3.8), RUGGEDCOM RS900M-STND-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-STND-XX (All versions < V4.3.8), RUGGEDCOM RS900W (All versions < V4.3.8), RUGGEDCOM RS910 (All versions < V4.3.8), RUGGEDCOM RS910L (All versions < V4.3.8), RUGGEDCOM RS910W (All versions < V4.3.8), RUGGEDCOM RS920L (All versions < V4.3.8), RUGGEDCOM RS920W (All versions < V4.3.8), RUGGEDCOM RS930L (All versions < V4.3.8), RUGGEDCOM RS930W (All versions < V4.3.8), RUGGEDCOM RS940G (All versions < V4.3.8), RUGGEDCOM RS969 (All versions < V4.3.8), RUGGEDCOM RSG2100 (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2100P (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2200 (All versions < V4.3.8), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2288 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300P V5.X (All versions < V5.7.0), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2488 V5.X (All versions < V5.7.0), RUGGEDCOM RSG907R (All versions < V5.7.0), RUGGEDCOM RSG908C (All versions < V5.7.0), RUGGEDCOM RSG909R (All versions < V5.7.0), RUGGEDCOM RSG910C (All versions < V5.7.0), RUGGEDCOM RSG920P V4.X (All versions < V4.3.8), RUGGEDCOM RSG920P V5.X (All versions < V5.7.0), RUGGEDCOM RSL910 (All versions < V5.7.0), RUGGEDCOM RST2228 (All versions < V5.7.0), RUGGEDCOM RST2228P (All versions < V5.7.0), RUGGEDCOM RST916C (All versions < V5.7.0), RUGGEDCOM RST916P (All versions < V5.7.0). The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device.

Severity

CVSS 3.1

6.7 medium
CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H
EPSS
0.4% (unchanged from 0.4% a week ago; 0.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 32nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: partial, assessed 2025-04-18. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-326 Inadequate Encryption Strength
CWE-311 Missing Encryption of Sensitive Data
OWASP Top 10
A04:2025 Cryptographic Failures, A06:2025 Insecure Design
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-37209 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-37209?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-37209?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-37209 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens RUGGEDCOM i800before V4.3.8
Siemens RUGGEDCOM i801before V4.3.8
Siemens RUGGEDCOM i802before V4.3.8
Siemens RUGGEDCOM i803before V4.3.8
Siemens RUGGEDCOM M2100before V4.3.8
Siemens RUGGEDCOM M2200before V4.3.8
Siemens RUGGEDCOM M969before V4.3.8
Siemens RUGGEDCOM RMC30before V4.3.8
Siemens RUGGEDCOM RMC8388 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RMC8388 V5.Xbefore V5.7.0
Siemens RUGGEDCOM RP110before V4.3.8
Siemens RUGGEDCOM RS1600before V4.3.8
Siemens RUGGEDCOM RS1600Fbefore V4.3.8
Siemens RUGGEDCOM RS1600Tbefore V4.3.8
Siemens RUGGEDCOM RS400before V4.3.8
Siemens RUGGEDCOM RS401before V4.3.8
Siemens RUGGEDCOM RS416before V4.3.8
Siemens RUGGEDCOM RS416Pbefore V4.3.8
Siemens RUGGEDCOM RS416Pv2 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RS416Pv2 V5.Xbefore V5.7.0
Siemens RUGGEDCOM RS416v2 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RS416v2 V5.Xbefore V5.7.0
Siemens RUGGEDCOM RS8000before V4.3.8
Siemens RUGGEDCOM RS8000Abefore V4.3.8
Siemens RUGGEDCOM RS8000Hbefore V4.3.8
Siemens RUGGEDCOM RS8000Tbefore V4.3.8
Siemens RUGGEDCOM RS900before V4.3.8
Siemens RUGGEDCOM RS900 (32M) V4.Xbefore V4.3.8
Siemens RUGGEDCOM RS900 (32M) V5.Xbefore V5.7.0
Siemens RUGGEDCOM RS900Gbefore V4.3.8
Siemens RUGGEDCOM RS900G (32M) V4.Xbefore V4.3.8
Siemens RUGGEDCOM RS900G (32M) V5.Xbefore V5.7.0
Siemens RUGGEDCOM RS900GPbefore V4.3.8
Siemens RUGGEDCOM RS900Lbefore V4.3.8
Siemens RUGGEDCOM RS900M-GETS-C01before V4.3.8
Siemens RUGGEDCOM RS900M-GETS-XXbefore V4.3.8
Siemens RUGGEDCOM RS900M-STND-C01before V4.3.8
Siemens RUGGEDCOM RS900M-STND-XXbefore V4.3.8
Siemens RUGGEDCOM RS900Wbefore V4.3.8
Siemens RUGGEDCOM RS910before V4.3.8
Siemens RUGGEDCOM RS910Lbefore V4.3.8
Siemens RUGGEDCOM RS910Wbefore V4.3.8
Siemens RUGGEDCOM RS920Lbefore V4.3.8
Siemens RUGGEDCOM RS920Wbefore V4.3.8
Siemens RUGGEDCOM RS930Lbefore V4.3.8
Siemens RUGGEDCOM RS930Wbefore V4.3.8
Siemens RUGGEDCOM RS940Gbefore V4.3.8
Siemens RUGGEDCOM RS969before V4.3.8
Siemens RUGGEDCOM RSG2100before V4.3.8
Siemens RUGGEDCOM RSG2100 (32M) V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2100 (32M) V5.Xbefore V5.7.0
Siemens RUGGEDCOM RSG2100Pbefore V4.3.8
Siemens RUGGEDCOM RSG2100P (32M) V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2100P (32M) V5.Xbefore V5.7.0
Siemens RUGGEDCOM RSG2200before V4.3.8
Siemens RUGGEDCOM RSG2288 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2288 V5.Xbefore V5.7.0
Siemens RUGGEDCOM RSG2300 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2300 V5.Xbefore V5.7.0
Siemens RUGGEDCOM RSG2300P V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2300P V5.Xbefore V5.7.0
Siemens RUGGEDCOM RSG2488 V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG2488 V5.Xbefore V5.7.0
Siemens RUGGEDCOM RSG907Rbefore V5.7.0
Siemens RUGGEDCOM RSG908Cbefore V5.7.0
Siemens RUGGEDCOM RSG909Rbefore V5.7.0
Siemens RUGGEDCOM RSG910Cbefore V5.7.0
Siemens RUGGEDCOM RSG920P V4.Xbefore V4.3.8
Siemens RUGGEDCOM RSG920P V5.Xbefore V5.7.0
Siemens RUGGEDCOM RSL910before V5.7.0
Siemens RUGGEDCOM RST2228before V5.7.0
Siemens RUGGEDCOM RST2228Pbefore V5.7.0
Siemens RUGGEDCOM RST916Cbefore V5.7.0
Siemens RUGGEDCOM RST916Pbefore V5.7.0

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-22-069-01Siemens RUGGEDCOM Devices2022-03-08Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and FacilitiesRUGGEDCOM i800, RUGGEDCOM i801, RUGGEDCOM i802 and 47 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-20 Encryption Brute Forcing Likelihood: Low · Severity: Low
  • CAPEC-112 Brute Force Severity: High
  • CAPEC-192 Protocol Analysis Likelihood: Low · Severity: Low

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-311 (14).