cve.bz

CVE-2021-35527 hitachienergy esoms: Insufficiently Protected Credentials

7.5 highEPSS 1.0%

High (7.5) in hitachienergy esoms. EPSS 1.0% estimated probability of exploitation activity in the next 30 days.

On this page
Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions.

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS
1.0% (unchanged from 1.0% a week ago; 1.0% 30 days ago) estimated probability of exploitation activity in the next 30 days; 64th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWEs
CWE-522 Insufficiently Protected Credentials
CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
OWASP Top 10
A01:2025 Broken Access Control, A06:2025 Insecure Design
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-35527 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-35527?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-35527?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-35527 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Hitachi ABB Power Grids eSOMSthrough 6.3

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-210-01Hitachi ABB Power Grids eSOMS2021-07-29EnergyeSOMS: All Versions 6.3 and priornone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-522 (13), CWE-200 (59).

References

Check your stackJSON