cve.bz

CVE-2021-32976 moxa: Out-of-bounds Write

9.8 criticalEPSS 2.8%

Critical (9.8) in moxa. EPSS 2.8% estimated probability of exploitation activity in the next 30 days.

On this page
Five buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to initiate a denial-of-service attack and execute arbitrary code.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
2.8% (unchanged from 2.8% a week ago; 2.8% 30 days ago) estimated probability of exploitation activity in the next 30 days; 87th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2025-04-16. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWEs
CWE-787 Out-of-bounds Write
CWE-121 Stack-based Buffer Overflow
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-32976 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-32976?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-32976?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-32976 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

  • moxa:nport_iaw5150a-12i\/o_firmware
  • moxa:nport_iaw5150a-6i\/o_firmware
  • moxa:nport_iaw5250a-12i\/o_firmware
  • moxa:nport_iaw5250a-6i\/o_firmware

Versions

From the CNA's record in the CVE List.

ProductAffected
Moxa NPort IAW5000A-I/O series firmwarethrough 2.2

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-187-01Moxa NPort IAW5000A-I/O Series Serial Device Server2021-07-06Energy SectorNPort IAW5000A-I/O Series firmware: Version 2.2 or earliernone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

References