cve.bz

CVE-2021-31340 siemens: Uncontrolled Resource Consumption

7.5 highEPSS 1.0%Fix available

High (7.5) in siemens. EPSS 1.0% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
1.0% (unchanged from 1.0% a week ago; 1.0% 30 days ago) estimated probability of exploitation activity in the next 30 days; 62nd percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-400 Uncontrolled Resource Consumption
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-31340 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-31340?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-31340?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-31340 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:simatic_rf166c_firmwareafter 1.1 before 1.3.2
siemens:simatic_rf185c_firmwareafter 1.1 before 1.3.2
siemens:simatic_rf186c_firmwareafter 1.1 before 1.3.2
siemens:simatic_rf186ci_firmwareafter 1.1 before 1.3.2
siemens:simatic_rf188c_firmwareafter 1.1 before 1.3.2
siemens:simatic_rf188ci_firmwareafter 1.1 before 1.3.2
siemens:simatic_rf360r_firmwarebefore 2.0
siemens:simatic_reader_rf610r_cmiit_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf610r_etsi_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf610r_fcc_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf615r_cmiit_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf615r_etsi_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf615r_fcc_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf650r_cmiit_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf650r_etsi_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf650r_fcc_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf650r_arib_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf680r_cmiit_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf680r_etsi_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf680r_fcc_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf680r_arib_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf685r_cmiit_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf685r_etsi_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf685r_fcc_firmwarefrom 3.0 before 4.0
siemens:simatic_reader_rf685r_arib_firmwarefrom 3.0 before 4.0

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-159-13Siemens SIMATIC RFID (Update B)2021-06-08MultipleSIMATIC Reader RF610R CMIIT, SIMATIC Reader RF610R ETSI, SIMATIC Reader RF610R FCC and 22 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-147 XML Ping of the Death Likelihood: Low · Severity: Medium
  • CAPEC-227 Sustained Client Engagement
  • CAPEC-492 Regular Expression Exponential Blowup

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON