cve.bz

CVE-2021-27428 ge

9.8 criticalEPSS 1.2%

Critical (9.8) in ge. EPSS 1.2% estimated probability of exploitation activity in the next 30 days.

On this page
GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The weakness is assessed, and mitigation is implemented in firmware Version 8.10.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
1.2% (unchanged from 1.2% a week ago; 1.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 69th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2025-04-16. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-434 Unrestricted Upload of File with Dangerous Type
OWASP Top 10
A06:2025 Insecure Design
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-27428 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-27428?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-27428?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-27428 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
GE UR familybefore 8.1x

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-075-02GE UR Family (Update A)2021-03-16Communications, Critical Manufacturing, Energy, Healthcare and Public Health, Transportation Systems, Water and Wastewater SystemsGE Veronva UR B30: <8.10, GE Veronva UR B90: <8.10, GE Veronva UR C30: <8.10 and 16 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON