CVE-2021-25676 siemens

7.5 highEPSS 1.3%

High (7.5) in siemens. EPSS 1.3% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
1.3% (unchanged from 1.3% a week ago; 1.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 72nd percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-307 Improper Restriction of Excessive Authentication Attempts
OWASP Top 10
A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-25676 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-25676?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-25676?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-25676 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:ruggedcom_rm1224_firmware6.3
siemens:scalance_m-800_firmware6.3
siemens:scalance_s615_firmware6.3
siemens:scalance_sc-600_firmwarefrom 2.1 before 2.1.3

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-068-02Siemens SCALANCE and RUGGEDCOM Devices SSH (Update A)2021-03-09MultipleRUGGEDCOM RM1224, SCALANCE M-800, SCALANCE S615 and 1 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-16 Dictionary-based Password Attack Likelihood: Medium · Severity: High
  • CAPEC-49 Password Brute Forcing Likelihood: Medium · Severity: High
  • CAPEC-560 Use of Known Domain Credentials Likelihood: High · Severity: High
  • CAPEC-565 Password Spraying Likelihood: High · Severity: High
  • CAPEC-600 Credential Stuffing Likelihood: High · Severity: High
  • CAPEC-652 Use of Known Kerberos Credentials Likelihood: Medium · Severity: High
  • CAPEC-653 Use of Known Operating System Credentials Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON