CVE-2021-22804 schneider-electric interactive graphical scada system data collector: Path traversal

7.5 highEPSS 1.3%Fix available

High (7.5) in schneider-electric interactive graphical scada system data collector. EPSS 1.3% estimated probability of exploitation activity in the next 30 days.

On this page
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS
1.3% (unchanged from 1.3% a week ago; 1.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 71st percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-22 Improper Limitation of a Pathname to a Restricted Directory (Path traversal)
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-22804 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-22804?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-22804?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-22804 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:interactive_graphical_scada_system_data_collectorthrough 15.0.0.21243

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-285-03Schneider Electric IGSS2021-10-12Commercial Facilities, Critical Manufacturing, EnergyIGSS Data Collector (dc.exe): v15.0.0.21243 and priornone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-64 Using Slashes and URL Encoding Combined to Bypass Validation Logic Likelihood: High · Severity: High
  • CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
  • CAPEC-78 Using Escaped Slashes in Alternate Encoding Likelihood: High · Severity: High
  • CAPEC-79 Using Slashes in Alternate Encoding Likelihood: High · Severity: High
  • CAPEC-126 Path Traversal Likelihood: High · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON