cve.bz

CVE-2021-22799 schneider-electric software update: Insufficient Entropy

3.8 lowEPSS 0.2%Fix available

Low (3.8) in schneider-electric software update. EPSS 0.2% estimated probability of exploitation activity in the next 30 days.

On this page
A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1

Severity

CVSS 3.1

3.8 low
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N
EPSS
0.2% (unchanged from 0.2% a week ago; 0.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 16th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-331 Insufficient Entropy
OWASP Top 10
A04:2025 Cryptographic Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-22799 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-22799?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-22799?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-22799 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:software_updatefrom 2.3.0 before 2.5.2

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-336-01Schneider Electric SESU2021-12-02Commercial Facilities, Critical Manufacturing, EnergySchneider Electric Software Update: v2.3.0 through v2.5.1none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-59 Session Credential Falsification through Prediction Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON