cve.bz

CVE-2021-22794 schneider-electric struxureware data center expert: Path traversal

9.8 criticalEPSS 2.2%

Critical (9.8) in schneider-electric struxureware data center expert. EPSS 2.2% estimated probability of exploitation activity in the next 30 days.

On this page
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
2.2% (unchanged from 2.2% a week ago; 2.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 83rd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-22 Improper Limitation of a Pathname to a Restricted Directory (Path traversal)
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-22794 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-22794?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-22794?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-22794 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Schneider Electric StruxureWare Data Center Expertbefore V7.8.1

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-257-03Schneider Electric Struxureware Data Center Expert2021-09-14Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater SystemsStruxureware Data Center: Expert Versions 7.8.1 and priornone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-64 Using Slashes and URL Encoding Combined to Bypass Validation Logic Likelihood: High · Severity: High
  • CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
  • CAPEC-78 Using Escaped Slashes in Alternate Encoding Likelihood: High · Severity: High
  • CAPEC-79 Using Slashes in Alternate Encoding Likelihood: High · Severity: High
  • CAPEC-126 Path Traversal Likelihood: High · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON