cve.bz

CVE-2021-22711 schneider-electric interactive graphical scada system

7.8 highEPSS 0.9%Fix available

High (7.8) in schneider-electric interactive graphical scada system. EPSS 0.9% estimated probability of exploitation activity in the next 30 days.

On this page
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to missing validation of input data.

Severity

CVSS 3.1

7.8 high
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS
0.9% (unchanged from 0.9% a week ago; 0.9% 30 days ago) estimated probability of exploitation activity in the next 30 days; 60th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-22711 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-22711?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-22711?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-22711 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:interactive_graphical_scada_systemthrough 15.0.0.21041

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-070-01Schneider Electric IGSS SCADA Software2021-03-11Commercial Facilities, Critical Manufacturing, EnergyIGSS Definition (Def.exe): Version 15.0.0.21041 and priornone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-119 (12).

References

Check your stackJSON