cve.bz

CVE-2021-21812 att xmill: Out-of-bounds Write

7.8 highExploit referenceEPSS 0.3%

High (7.8) in att xmill. EPSS 0.3% estimated probability of exploitation activity in the next 30 days.

On this page
A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT&T Labs’ Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a static sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger these vulnerabilities.

Severity

CVSS 3.1

7.8 high
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS
0.3% (unchanged from 0.3% a week ago; 0.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 27th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-787 Out-of-bounds Write
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2021-21812 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-21812?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-21812?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-21812 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
att:xmill0.7

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-22-223-03Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x702022-08-11EcoStruxure Control Expert: All versions (including former Unity Pro) prior to V15.1 HF001, EcoStruxure Process Expert: All versions (including former HDCS) prior to V2021, SCADAPack RemoteConnect for x70: All versions prior to R2.7.3none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

References

Check your stackJSON