CVE-2021-20607 mitsubishielectric: Integer Underflow (Wrap or Wraparound)

5.5 mediumEPSS 1.0%Fix available

Medium (5.5) in mitsubishielectric. EPSS 1.0% estimated probability of exploitation activity in the next 30 days.

On this page
Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker.

Severity

CVSS 3.1

5.5 medium
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
EPSS
1.0% (unchanged from 1.0% a week ago; 1.0% 30 days ago) estimated probability of exploitation activity in the next 30 days; 63rd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-191 Integer Underflow (Wrap or Wraparound)
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2021-20607 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2021-20607?via=ask-ai-copy and https://cve.bz/cve/CVE-2021-20607?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2021-20607 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
mitsubishielectric:ezsocketthrough 5.4
mitsubishielectric:gx_works2through 1.606g

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-350-05Mitsubishi Electric FA Engineering Software (Update B)2021-12-16Critical ManufacturingEZSocket: Versions 5.4 and prior, GX Works2: Versions 1.606G and prior, MELSOFT Navigator: Versions 2.84N and priornone listed