cve.bz

CVE-2020-7547 schneider-electric: Improper Access Control

8.8 highEPSS 1.3%

High (8.8) in schneider-electric. EPSS 1.3% estimated probability of exploitation activity in the next 30 days.

On this page
A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.

Severity

CVSS 3.1

8.8 high
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS
1.3% (unchanged from 1.3% a week ago; 1.3% 30 days ago) estimated probability of exploitation activity in the next 30 days; 71st percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-284 Improper Access Control
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2020-7547 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2020-7547?via=ask-ai-copy and https://cve.bz/cve/CVE-2020-7547?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2020-7547 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
schneider-electric:ecostruxure_energy_expert2.0
schneider-electric:ecostruxure_power_monitoring_expert7.0
schneider-electric:ecostruxure_power_monitoring_expert8.0
schneider-electric:ecostruxure_power_monitoring_expert9.0
schneider-electric:power_manager1.1
schneider-electric:power_manager1.2
schneider-electric:power_manager1.3
schneider-electric:powerscada_expert_with_advanced_reporting_and_dashboards8.0
schneider-electric:powerscada_operation_with_advanced_reporting_and_dashboards9.0

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-284 (17).

References

Check your stackJSON