cve.bz

CVE-2020-15799 siemens

6.5 mediumEPSS 1.1%

Medium (6.5) in siemens. EPSS 1.1% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.

Severity

CVSS 3.1

6.5 medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
EPSS
1.1% (unchanged from 1.1% a week ago; 1.1% 30 days ago) estimated probability of exploitation activity in the next 30 days; 66th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-306 Missing Authentication for Critical Functionality
OWASP Top 10
A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2020-15799 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2020-15799?via=ask-ai-copy and https://cve.bz/cve/CVE-2020-15799?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2020-15799 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:scalance_x200-4pirt_firmwarebefore 5.5.0
siemens:scalance_x201-3pirt_firmwarebefore 5.5.0
siemens:scalance_x202-2irt_firmwarebefore 5.5.0
siemens:scalance_x202-2pirt_firmwarebefore 5.5.0
siemens:scalance_x202-2pirt_siplus_net_firmwarebefore 5.5.0
siemens:scalance_x204irt_firmwarebefore 5.5.0
siemens:scalance_xb205-3_firmwarebefore 5.2.5
siemens:scalance_xb205-3ld_firmwarebefore 5.2.5
siemens:scalance_xb208_firmwarebefore 5.2.5
siemens:scalance_xb213-3_firmwarebefore 5.2.5
siemens:scalance_xb213-3ld_firmwarebefore 5.2.5
siemens:scalance_xb216_firmwarebefore 5.2.5
siemens:scalance_xc206-2_firmwarebefore 5.2.5
siemens:scalance_xc206-2g_poe__firmwarebefore 5.2.5
siemens:scalance_xc206-2g_poe_eec_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_eec_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_g_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_g_(e/ip)_firmwarebefore 5.2.5
siemens:scalance_xc206-2sfp_g_eec_firmwarebefore 5.2.5
siemens:scalance_xc208_firmwarebefore 5.2.5
siemens:scalance_xc208eec_firmwarebefore 5.2.5
siemens:scalance_xc208g_firmwarebefore 5.2.5
siemens:scalance_xc208g_(e/ip)_firmwarebefore 5.2.5
siemens:scalance_xc208g_eec_firmwarebefore 5.2.5
siemens:scalance_xc208g_poe_firmwarebefore 5.2.5
siemens:scalance_xc216_firmwarebefore 5.2.5
siemens:scalance_xc216-4c_firmwarebefore 5.2.5
siemens:scalance_xc216-4c_g_firmwarebefore 5.2.5
siemens:scalance_xc216-4c_g_(e/ip)_firmwarebefore 5.2.5
siemens:scalance_xc216-4c_g_eec_firmwarebefore 5.2.5
siemens:scalance_xc216eec_firmwarebefore 5.2.5
siemens:scalance_xc224-4c_g__firmwarebefore 5.2.5
siemens:scalance_xc224-4c_g_(e/ip)_firmwarebefore 5.2.5
siemens:scalance_xc224-4c_g_eec_firmwarebefore 5.2.5
siemens:scalance_xc224__firmwarebefore 5.2.5
siemens:scalance_xf201-3p_irt_firmwarebefore 5.2.5
siemens:scalance_xf202-2p_irt_firmwarebefore 5.2.5
siemens:scalance_xf204_firmwarebefore 5.2.5
siemens:scalance_xf204-2_firmwarebefore 5.2.5
siemens:scalance_xf204-2ba_dna_firmwarebefore 5.2.5
siemens:scalance_xf204-2ba_irt_firmwarebefore 5.2.5
siemens:scalance_xf204_dna_firmwarebefore 5.2.5
siemens:scalance_xf204irt_firmwarebefore 5.2.5
siemens:scalance_xf206-1_firmwarebefore 5.2.5
siemens:scalance_xf208_firmwarebefore 5.2.5
siemens:scalance_xp208_firmwarebefore 5.2.5
siemens:scalance_xp208_(eip)_firmwarebefore 5.2.5
siemens:scalance_xp208eec_firmwarebefore 5.2.5
siemens:scalance_xp208poe_eec_firmwarebefore 5.2.5
siemens:scalance_xp216_firmwarebefore 5.2.5
siemens:scalance_xp216_(eip)_firmwarebefore 5.2.5
siemens:scalance_xp216eec_firmwarebefore 5.2.5
siemens:scalance_xp216poe_eec_firmwarebefore 5.2.5

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-012-05Siemens SCALANCE X Products (Update B)2021-01-12MultipleSCALANCE X-200 switch family (incl. SIPLUS NET variants), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-12 Choosing Message Identifier Likelihood: High · Severity: High
  • CAPEC-36 Using Unpublished Interfaces or Functionality Likelihood: Medium · Severity: High
  • CAPEC-62 Cross Site Request Forgery Likelihood: High · Severity: Very High
  • CAPEC-166 Force the System to Reset Values Severity: Medium
  • CAPEC-216 Communication Channel Manipulation

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON