CVE-2020-15786 siemens

9.8 criticalEPSS 1.5%

Critical (9.8) in siemens. EPSS 1.5% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
1.5% (unchanged from 1.5% a week ago; 1.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 75th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: yes · Technical impact: total, assessed 2026-06-02. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-307 Improper Restriction of Excessive Authentication Attempts
OWASP Top 10
A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2020-15786 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2020-15786?via=ask-ai-copy and https://cve.bz/cve/CVE-2020-15786?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2020-15786 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:simatic_hmi_basic_panels_2nd_generation_firmwarethrough 14

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-20-252-06Siemens SIMATIC HMI Products (Update A)2020-09-08MultipleSIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants), SIMATIC HMI Comfort Panels (incl. SIPLUS variants), SIMATIC HMI Mobile Panels and 1 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-16 Dictionary-based Password Attack Likelihood: Medium · Severity: High
  • CAPEC-49 Password Brute Forcing Likelihood: Medium · Severity: High
  • CAPEC-560 Use of Known Domain Credentials Likelihood: High · Severity: High
  • CAPEC-565 Password Spraying Likelihood: High · Severity: High
  • CAPEC-600 Credential Stuffing Likelihood: High · Severity: High
  • CAPEC-652 Use of Known Kerberos Credentials Likelihood: Medium · Severity: High
  • CAPEC-653 Use of Known Operating System Credentials Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON