CVSS 3.1
9.8 criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HCritical (9.8) in mitsubishielectric. EPSS 0.9% estimated probability of exploitation activity in the next 30 days.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HExplain CVE-2020-14496 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2020-14496?via=ask-ai-copy and https://cve.bz/cve/CVE-2020-14496?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2020-14496 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
From the CNA's record in the CVE List.
| Product | Affected |
|---|---|
| Mitsubishi Electric CPU Module Logging Configuration Tool | from All through 1.100E |
| Mitsubishi Electric CW Configurator | from All through 1.010L |
| Mitsubishi Electric Data Transfer | from All through 3.40S |
| Mitsubishi Electric EZSocket | from All through 4.5 |
| Mitsubishi Electric FR Configurator2 | from All through 1.22Y |
| Mitsubishi Electric GT Designer3 Version1 (GOT2000) | from All through 1.235V |
| Mitsubishi Electric GT SoftGOT1000 Version3 | from All through 3.200J |
| Mitsubishi Electric GT SoftGOT1000 Version3 | All |
| Mitsubishi Electric GT SoftGOT2000 Version1 | from All through 1.235V |
| Mitsubishi Electric GX LogViewer | from All through 1.100E |
| Mitsubishi Electric GX Works2 | from All through 1.592S |
| Mitsubishi Electric GX Works3 | from All through 1.063R |
| Mitsubishi Electric M_CommDTM-HART | All 1.00A |
| Mitsubishi Electric M_CommDTM-IO-Link | All |
| Mitsubishi Electric MELFA-Works | from All through 4.3 |
| Mitsubishi Electric MELSEC WinCPU Setting Utility | All |
| Mitsubishi Electric MELSOFT EM Software Development Kit (EM Configurator) | from All through 1.010L |
| Mitsubishi Electric MELSOFT FieldDeviceConfigurator | from All through 1.03D |
| Mitsubishi Electric MELSOFT Navigator | from All through 2.62Q |
| Mitsubishi Electric MH11 SettingTool Version2 | from All through 2.002C |
| Mitsubishi Electric MI Configurator | All |
| Mitsubishi Electric Motorizer | from All through 1.005F |
| Mitsubishi Electric MR Configurator2 | from All through 1.105K |
| Mitsubishi Electric MT Works2 | from All through 1.156N |
| Mitsubishi Electric MX Component | from All through 4.19V |
| Mitsubishi Electric Network Interface Board CC IE Control utility | All |
| Mitsubishi Electric Network Interface Board CC IE Field Utility | All |
| Mitsubishi Electric Network Interface Board CC-Link Ver.2 Utility | All |
| Mitsubishi Electric Network Interface Board MNETH utility | All |
| Mitsubishi Electric PX Developer | from All through 1.52E |
| Mitsubishi Electric RT ToolBox2 | from All through 3.72A |
| Mitsubishi Electric RT ToolBox3 | from All through 1.70Y |
| Mitsubishi Electric Setting/monitoring tools for the C Controller module | All |
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-20-212-02 | ICSA-20-212-02_Mitsubishi Electric Multiple Factory Automation Engineering Software Products (Update A) | 2020-07-30 | Data Transfer: Versions 3.40S and prior, MELSOFT FieldDeviceConfigurator: Versions 1.03D and prior, GT SoftGOT2000 Version1 Bersions: 1.235V and prior and 30 more | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.