cve.bz

CVE-2020-12005 rockwellautomation

7.5 highEPSS 1.8%

High (7.5) in rockwellautomation. EPSS 1.8% estimated probability of exploitation activity in the next 30 days.

On this page
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
1.8% (unchanged from 1.8% a week ago; 1.8% 30 days ago) estimated probability of exploitation activity in the next 30 days; 80th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-434 Unrestricted Upload of File with Dangerous Type
OWASP Top 10
A06:2025 Insecure Design
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2020-12005 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2020-12005?via=ask-ai-copy and https://cve.bz/cve/CVE-2020-12005?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2020-12005 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
rockwellautomation:factorytalk_linx6.00
rockwellautomation:factorytalk_linx6.10
rockwellautomation:factorytalk_linx6.11
rockwellautomation:rslinx_classicthrough 4.11.00

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-20-163-02Rockwell Automation FactoryTalk Linx Software (Update A)2020-06-11Critical Manufacturing, Energy, Water and Wastewater SystemsRSLinx Classic: v4.11.00 and prior (Versions removed from the scope of this advisory), FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later and 6 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON