CVE-2020-12003 rockwellautomation: Path traversal

7.5 highEPSS 5.4%

High (7.5) in rockwellautomation. EPSS 5.4% estimated probability of exploitation activity in the next 30 days.

On this page
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.

Severity

CVSS 3.1

7.5 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS
5.4% (unchanged from 5.4% a week ago; 5.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 93rd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-22 Improper Limitation of a Pathname to a Restricted Directory (Path traversal)
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2020-12003 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2020-12003?via=ask-ai-copy and https://cve.bz/cve/CVE-2020-12003?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2020-12003 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
rockwellautomation:factorytalk_linx6.00
rockwellautomation:factorytalk_linx6.10
rockwellautomation:factorytalk_linx6.11
rockwellautomation:rslinx_classicthrough 4.11.00

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-20-163-02Rockwell Automation FactoryTalk Linx Software (Update A)2020-06-11Critical Manufacturing, Energy, Water and Wastewater SystemsRSLinx Classic: v4.11.00 and prior (Versions removed from the scope of this advisory), FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later and 6 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-64 Using Slashes and URL Encoding Combined to Bypass Validation Logic Likelihood: High · Severity: High
  • CAPEC-76 Manipulating Web Input to File System Calls Likelihood: High · Severity: Very High
  • CAPEC-78 Using Escaped Slashes in Alternate Encoding Likelihood: High · Severity: High
  • CAPEC-79 Using Slashes in Alternate Encoding Likelihood: High · Severity: High
  • CAPEC-126 Path Traversal Likelihood: High · Severity: Very High