cve.bz

CVE-2020-11915 svakom siime eye firmware

6.8 mediumExploit referenceEPSS 0.6%

Medium (6.8) in svakom siime eye firmware. EPSS 0.6% estimated probability of exploitation activity in the next 30 days.

On this page
An issue was discovered in Svakom Siime Eye 14.1.00000001.3.330.0.0.3.14. By sending a set_params.cgi?telnetd=1&save=1&reboot=1 request to the webserver, it is possible to enable the telnet interface on the device. The telnet interface can then be used to obtain access to the device with root privileges via a reecam4debug default password. This default telnet password is the same across all Siime Eye devices. In order for the attack to be exploited, an attacker must be physically close in order to connect to the device's Wi-Fi access point.

Severity

CVSS 3.1

6.8 medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.6% (unchanged from 0.6% a week ago; 0.6% 30 days ago) estimated probability of exploitation activity in the next 30 days; 49th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CISA's assessment (SSVC)
Exploitation: none · Automatable: no · Technical impact: total, assessed 2024-07-30. From CISA's Vulnrichment in the CVE List: whether it is exploited, whether exploiting it can be automated, and how much control it gives.
CWE
CWE-1188 Initialization of a Resource with an Insecure Default
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2020-11915 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2020-11915?via=ask-ai-copy and https://cve.bz/cve/CVE-2020-11915?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2020-11915 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
svakom:siime_eye_firmware14.1.00000001.3.330.0.0.3.14

Attack patterns (CAPEC)

  • CAPEC-665 Exploitation of Thunderbolt Protection Flaws Likelihood: Low · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON