UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.

Severity

CVSS 3.1

9.8 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
4.0% (unchanged from 4.0% a week ago; 4.0% 30 days ago) estimated probability of exploitation activity in the next 30 days; 91st percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-170 Improper Null Termination
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2019-8275 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2019-8275?via=ask-ai-copy and https://cve.bz/cve/CVE-2019-8275?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2019-8275 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

  • siemens:sinumerik_access_mymachine\/p2p
  • siemens:sinumerik_pcu_base_win10_software\/ipc
  • siemens:sinumerik_pcu_base_win7_software\/ipc
  • uvnc:ultravnc

Versions

From the NVD's CPE matches.

ProductAffected
uvnc:ultravncbefore 1.2.2.3
siemens:sinumerik_access_mymachine/p2pbefore 4.8
siemens:sinumerik_pcu_base_win10_software/ipcbefore 14.00
siemens:sinumerik_pcu_base_win7_software/ipcthrough 12.01

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-21-131-04Siemens SINAMICS Medium Voltage Products Remote Access (Update B)2021-05-11MultipleSINAMICS GH150, SINAMICS GL150 (with option X30), SINAMICS GM150 (with option X30) and 5 morenone listed
ICSA-21-131-11Siemens SIMATIC UltraVNC HMI WinCC Products2021-05-11MultipleSIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F and 1 morenone listed
ICSA-20-161-06Siemens SINUMERIK2020-06-09MultipleSiemens SINUMERIK Access MyMachine /P2P: All versions < V4.8, Siemens SINUMERIK PCU base Win10 software /IPC: All versions < V14.00, Siemens SINUMERIK PCU base Win7 software /IPC: All versions < V12.01 HF4none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.