Critical (9.1) in bosch. EPSS 1.5% estimated probability of exploitation activity in the next 30 days.

On this page
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.

Severity

CVSS 3.1

9.1 critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
EPSS
1.5% (unchanged from 1.5% a week ago; 1.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 75th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-306 Missing Authentication for Critical Functionality
OWASP Top 10
A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2019-6958 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2019-6958?via=ask-ai-copy and https://cve.bz/cve/CVE-2019-6958?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2019-6958 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
bosch:access_professional_editionfrom 3.0 through 3.7
bosch:bosch_video_clientbefore 1.7.6.079
bosch:bosch_video_management_systemthrough 9.0
bosch:building_integration_systemfrom 2.2 through 4.4
bosch:building_integration_system4.5
bosch:building_integration_system4.6
bosch:building_integration_system4.6.1
bosch:configuration_managerbefore 6.10
bosch:video_sdkbefore 6.32.0099
bosch:dip_2000_firmwarebefore 0380.037
bosch:dip_5000_firmwarebefore 038.037
bosch:access_easy_controller_firmware2.1.8.5
bosch:access_easy_controller_firmware2.1.9.0
bosch:access_easy_controller_firmware2.1.9.1
bosch:access_easy_controller_firmware2.1.9.3

Attack patterns (CAPEC)

  • CAPEC-12 Choosing Message Identifier Likelihood: High · Severity: High
  • CAPEC-36 Using Unpublished Interfaces or Functionality Likelihood: Medium · Severity: High
  • CAPEC-62 Cross Site Request Forgery Likelihood: High · Severity: Very High
  • CAPEC-166 Force the System to Reset Values Severity: Medium
  • CAPEC-216 Communication Channel Manipulation

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON