A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.

Severity

CVSS 3.1

6.8 medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.5% (unchanged from 0.5% a week ago; 0.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 47th percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-749 Exposed Dangerous Method or Function
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2019-13945 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2019-13945?via=ask-ai-copy and https://cve.bz/cve/CVE-2019-13945?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2019-13945 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:simatic_s7-200_smart_cpu_st20_firmwarethrough 2.5.0
siemens:simatic_s7-200_smart_cpu_st30_firmwarethrough 2.5.0
siemens:simatic_s7-200_smart_cpu_st40_firmwarethrough 2.5.0
siemens:simatic_s7-200_smart_cpu_st60_firmwarethrough 2.5.0
siemens:simatic_s7-200_smart_cpu_sr20_firmwarethrough 2.5.0
siemens:simatic_s7-200_smart_cpu_sr30_firmwarethrough 2.5.0
siemens:simatic_s7-200_smart_cpu_sr40_firmwarethrough 2.5.0
siemens:simatic_s7-200_smart_cpu_sr60_firmwarethrough 2.5.0
siemens:simatic_s7-200_smart_cpu_cr40_firmwarethrough 2.2.2
siemens:simatic_s7-200_smart_cpu_cr60_firmwarethrough 2.2.2
siemens:simatic_s7-200_smart_cpu_cr20s_firmwarethrough 2.3.0
siemens:simatic_s7-200_smart_cpu_cr30s_firmwarethrough 2.3.0
siemens:simatic_s7-200_smart_cpu_cr40s_firmwarethrough 2.3.0
siemens:simatic_s7-200_smart_cpu_cr60s_firmwarethrough 2.3.0

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-19-318-02Siemens S7-1200 and S7-200 SMART CPUs (Update B)2019-11-12MultipleSiemens SIMATIC S7-1200 CPU family V4.x (incl.'SIPLUS variants): All versions with Function State (FS) < 11, Siemens SIMATIC S7-1200 CPU family < V4.x (incl.'SIPLUS variants): All versions, Siemens SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0): All versions <= V2.5.0 and Function State (FS) <= 9 and 13 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON