cve.bz

CVE-2019-10942 siemens: Uncontrolled Resource Consumption

8.6 highEPSS 1.4%

High (8.6) in siemens. EPSS 1.4% estimated probability of exploitation activity in the next 30 days.

On this page
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.

Severity

CVSS 3.1

8.6 high
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
EPSS
1.4% (unchanged from 1.4% a week ago; 1.4% 30 days ago) estimated probability of exploitation activity in the next 30 days; 72nd percentile. Scored 2026-11-21. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-400 Uncontrolled Resource Consumption
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2019-10942 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2019-10942?via=ask-ai-copy and https://cve.bz/cve/CVE-2019-10942?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2019-10942 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the CNA's record in the CVE List.

ProductAffected
Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants)All versions < V5.2.5
Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)All versions < V5.5.0
Siemens SCALANCE X204RNA (HSR)All versions
Siemens SCALANCE X204RNA (PRP)All versions
Siemens SCALANCE X204RNA EEC (HSR)All versions
Siemens SCALANCE X204RNA EEC (PRP)All versions
Siemens SCALANCE X204RNA EEC (PRP/HSR)All versions

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-19-225-03ICSA-19-225-03_Siemens SCALANCE X Switches (Update D)2019-08-13SCALANCE X-200RNA: All versionsnone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-147 XML Ping of the Death Likelihood: Low · Severity: Medium
  • CAPEC-227 Sustained Client Engagement
  • CAPEC-492 Regular Expression Exponential Blowup

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References