CVSS 3.1
7.5 highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HHigh (7.5) in siemens. EPSS 1.4% estimated probability of exploitation activity in the next 30 days.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HExplain CVE-2019-10923 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2019-10923?via=ask-ai-copy and https://cve.bz/cve/CVE-2019-10923?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2019-10923 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.
From the CNA's record in the CVE List.
| Product | Affected |
|---|---|
| Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller | All versions < V4.1.1 Patch 05 |
| Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 | All versions < V4.5.0 Patch 01 |
| Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P | All versions < V4.5.0 |
| Siemens SCALANCE X-200IRT family (incl. SIPLUS NET variants) | All versions < V5.2.1 |
| Siemens SIMATIC CP 1604 | All versions < V2.8 |
| Siemens SIMATIC CP 1616 | All versions < V2.8 |
| Siemens SIMATIC ET 200M (incl. SIPLUS variants) | All versions |
| Siemens SIMATIC ET 200MP IM 155-5 PN HF | before V4.2.0 |
| Siemens SIMATIC ET 200MP IM 155-5 PN ST | before V4.1.0 |
| Siemens SIMATIC ET 200pro IM 154-3 PN HF | all versions |
| Siemens SIMATIC ET 200pro IM 154-4 PN HF | all versions |
| Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU | All versions < V3.2.17 |
| Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU | All versions < V3.2.17 |
| Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU | All versions < V3.2.17 |
| Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU | All versions < V3.2.17 |
| Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU | All versions < V3.2.17 |
| Siemens SIMATIC ET 200SP IM 155-6 PN HF | before V4.2.0 |
| Siemens SIMATIC ET 200SP IM 155-6 PN ST | before V4.1.0 |
| Siemens SIMATIC ET 200SP IM 155-6 PN ST BA | before V4.1.0 |
| Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 | All versions |
| Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 | All versions |
| Siemens SIMATIC ET200ecoPN: IO-Link Master | All versions |
| Siemens SIMATIC ET200S (incl. SIPLUS variants) | All versions |
| Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) | All versions |
| Siemens SIMATIC S7-300 CPU 314C-2 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-300 CPU 315-2 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-300 CPU 315F-2 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-300 CPU 315T-3 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-300 CPU 317-2 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-300 CPU 317F-2 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-300 CPU 317T-3 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-300 CPU 319-3 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-300 CPU 319F-3 PN/DP | All versions < V3.2.17 |
| Siemens SIMATIC S7-400 CPU 412-2 PN V7 | before V7.0.3 |
| Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 | before V7.0.3 |
| Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 | before V7.0.3 |
| Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 | before V7.0.3 |
| Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 | before V7.0.3 |
| Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) | all versions |
| Siemens SIMATIC WinAC RTX 2010 | All versions < V2010 SP3 |
| Siemens SIMATIC WinAC RTX F 2010 | All versions < V2010 SP3 |
| Siemens SIMOTION | All versions |
| Siemens SINAMICS DCM | All versions < V1.5 HF1 |
| Siemens SINAMICS DCP | All versions < V1.3 |
| Siemens SINAMICS G110M V4.7 Control Unit | All versions < V4.7 SP10 HF5 |
| Siemens SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) | All versions < V4.7 SP10 HF5 |
| Siemens SINAMICS G130 | before V4.7 HF29 |
| Siemens SINAMICS G150 | before V4.7 HF29 |
| Siemens SINAMICS GH150 V4.7 Control Unit | All versions |
| Siemens SINAMICS GL150 V4.7 Control Unit | All versions |
| Siemens SINAMICS GM150 V4.7 Control Unit | All versions |
| Siemens SINAMICS S110 Control Unit | All versions |
| Siemens SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) | All versions < V4.7 HF34 |
| Siemens SINAMICS S150 | before V4.7 HF29 |
| Siemens SINAMICS SL150 V4.7 Control Unit | All versions < V4.7 HF33 |
| Siemens SINAMICS SM120 V4.7 Control Unit | All versions |
| Siemens SINUMERIK 828D | All versions < V4.8 SP5 |
| Siemens SINUMERIK 840D sl | All versions < V4.8 SP5 |
| Siemens SIPLUS ET 200MP IM 155-5 PN HF | before V4.2.0 |
| Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL | before V4.2.0 |
| Siemens SIPLUS ET 200MP IM 155-5 PN ST | before V4.1.0 |
| Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL | before V4.1.0 |
| Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU | All versions < V3.2.17 |
| Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU | All versions < V3.2.17 |
| Siemens SIPLUS ET 200SP IM 155-6 PN HF | before V4.2.0 |
| Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL | before V4.2.0 |
| Siemens SIPLUS ET 200SP IM 155-6 PN ST | before V4.1.0 |
| Siemens SIPLUS ET 200SP IM 155-6 PN ST BA | before V4.1.0 |
| Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL | before V4.1.0 |
| Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL | before V4.1.0 |
| Siemens SIPLUS S7-300 CPU 314C-2 PN/DP | All versions < V3.3.17 |
| Siemens SIPLUS S7-300 CPU 315-2 PN/DP | All versions < V3.2.17 |
| Siemens SIPLUS S7-300 CPU 315F-2 PN/DP | All versions < V3.2.17 |
| Siemens SIPLUS S7-300 CPU 317-2 PN/DP | All versions < V3.2.17 |
| Siemens SIPLUS S7-300 CPU 317F-2 PN/DP | All versions < V3.2.17 |
| Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 | before V7.0.3 |
| Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 | before V7.0.3 |
| Advisory | Title | Published | Sectors | Affected | Fixed |
|---|---|---|---|---|---|
| ICSA-19-283-01 | Siemens Industrial Real-Time (IRT) Devices | 2019-10-08 | Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P and 47 more | none listed |
From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.
The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.