cve.bz

CVE-2018-8840 Stack-based Buffer Overflow

9.8 criticalEPSS 8.6%

Critical (9.8). EPSS 8.6% estimated probability of exploitation activity in the next 30 days.

On this page
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.

Severity

CVSS 3.0

9.8 critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
8.6% (unchanged from 8.6% a week ago; 8.6% 30 days ago) estimated probability of exploitation activity in the next 30 days; 95th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWEs
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE-121 Stack-based Buffer Overflow
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2018-8840 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2018-8840?via=ask-ai-copy and https://cve.bz/cve/CVE-2018-8840?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2018-8840 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
indusoft:web_studiothrough 8.1
industrial-software:intouch_machine_edition_2017through 8.1

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-18-107-01Schneider Electric InduSoft Web Studio and InTouch Machine Edition2018-04-17Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems, and Water and Wastewater SystemsInTouch Machine Edition 2017: v8.1 and prior versions, InduSoft Web Studio: v8.1 and prior versionsnone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits. More on the page of CWE-119 (12).

References

Check your stackJSON