A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Severity

CVSS 3.0

5.9 medium
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
1.2% (unchanged from 1.2% a week ago; 1.2% 30 days ago) estimated probability of exploitation activity in the next 30 days; 68th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Fix and patched versions

Ask an AI about this CVE

Show the promptExplain CVE-2018-16563 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2018-16563?via=ask-ai-copy and https://cve.bz/cve/CVE-2018-16563?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2018-16563 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
siemens:siprotec_5_with_cpu_variant_cp100before 7.82
siemens:siprotec_5_with_cpu_variant_cp200before 7.58
siemens:siprotec_5_with_cpu_variant_cp300before 7.82
siemens:en100_ethernet_module_with_firmware_variant_iec_618504.35

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-19-043-02ICSA-19-043-02 Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays2019-02-12MultipleFirmware variant IEC 61850 for EN100 Ethernet module, Firmware variant MODBUS TCP for EN100 Ethernet module, Firmware variant DNP3 TCP for EN100 Ethernet module and 4 morenone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.