cve.bz

CVE-2017-9828 vivotek: OS Command Injection

9.8 criticalEPSS 82%

Critical (9.8) in vivotek. EPSS 82% estimated probability of exploitation activity in the next 30 days.

On this page
'/cgi-bin/admin/testserver.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable to shell command injection, which allows remote attackers to execute any shell command as root via a crafted HTTP request. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected. An attack uses shell metacharacters in the senderemail parameter.

Severity

CVSS 3.0

9.8 critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
82% (unchanged from 82% a week ago; 82% 30 days ago) estimated probability of exploitation activity in the next 30 days; 100th percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-78 Improper Neutralization of Special Elements used in an OS Command (OS Command Injection)
OWASP Top 10
A05:2025 Injection
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2017-9828 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2017-9828?via=ask-ai-copy and https://cve.bz/cve/CVE-2017-9828?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2017-9828 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
vivotek:network_camera_ib8369_firmwareib8369-vvtk-0102a
vivotek:network_camera_fd8164_firmwarefd8164-_vvtk-0200b
vivotek:network_camera_fd816ba_firmwarefd816ba-vvtk-010101.

Attack patterns (CAPEC)

  • CAPEC-6 Argument Injection Likelihood: High · Severity: High
  • CAPEC-15 Command Delimiters Likelihood: High · Severity: High
  • CAPEC-43 Exploiting Multiple Input Interpretation Layers Likelihood: Medium · Severity: High
  • CAPEC-88 OS Command Injection Likelihood: High · Severity: High
  • CAPEC-108 Command Line Execution through SQL Injection Likelihood: Low · Severity: Very High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON