cve.bz

CVE-2017-7915 moxa

9.8 criticalEPSS 1.5%

Critical (9.8) in moxa. EPSS 1.5% estimated probability of exploitation activity in the next 30 days.

On this page
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.

Severity

CVSS 3.0

9.8 critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
1.5% (unchanged from 1.5% a week ago; 1.5% 30 days ago) estimated probability of exploitation activity in the next 30 days; 75th percentile. Scored 2026-11-24. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-307 Improper Restriction of Excessive Authentication Attempts
OWASP Top 10
A07:2025 Authentication Failures
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2017-7915 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2017-7915?via=ask-ai-copy and https://cve.bz/cve/CVE-2017-7915?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2017-7915 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

Versions

From the NVD's CPE matches.

ProductAffected
moxa:oncell_g3110-hspa_firmwarethrough 1.3
moxa:oncell_g3110-hsdpa_firmwarethrough 1.2
moxa:oncell_g3150-hsdpa_firmwarethrough 1.4
moxa:oncell_5104-hsdpa_firmwarethrough -
moxa:oncell_5104-hspa_firmwarethrough -
moxa:oncell_5004-hspa_firmwarethrough -

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSA-17-143-01Moxa OnCell2017-05-23Commercial Facilities, Critical Manufacturing, Energy, Transportation SystemsOnCell G3110-HSDPA: Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA: Version 1.4 Build 11051315 and previous versions, OnCell G3110-HSPA: Version 1.3 build 15082117 and previous versionsnone listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-16 Dictionary-based Password Attack Likelihood: Medium · Severity: High
  • CAPEC-49 Password Brute Forcing Likelihood: Medium · Severity: High
  • CAPEC-560 Use of Known Domain Credentials Likelihood: High · Severity: High
  • CAPEC-565 Password Spraying Likelihood: High · Severity: High
  • CAPEC-600 Credential Stuffing Likelihood: High · Severity: High
  • CAPEC-652 Use of Known Kerberos Credentials Likelihood: Medium · Severity: High
  • CAPEC-653 Use of Known Operating System Credentials Likelihood: High · Severity: High

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON