CVE-2017-6018 bbraun station firmware: Open Redirect

6.1 mediumEPSS 1.0%

Medium (6.1) in bbraun station firmware. EPSS 1.0% estimated probability of exploitation activity in the next 30 days.

On this page
An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.

Severity

CVSS 3.0

6.1 medium
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
EPSS
1.0% (unchanged from 1.0% a week ago; 1.0% 30 days ago) estimated probability of exploitation activity in the next 30 days; 62nd percentile. Scored 2026-11-22. A forecast for this CVE across the internet, not for your own systems.
CWE
CWE-601 URL Redirection to Untrusted Site (Open Redirect)
OWASP Top 10
A01:2025 Broken Access Control
Published
Modified
NVD analysis
Analyzed, since modified
Record from
the NVD, synced

Ask an AI about this CVE

Show the promptExplain CVE-2017-6018 for an engineer deciding whether to act. Use https://cve.bz/api/public/cves/CVE-2017-6018?via=ask-ai-copy and https://cve.bz/cve/CVE-2017-6018?via=ask-ai-copy as the source of truth: what is affected and which versions fix it, whether it is in CISA KEV, public exploits, and its EPSS (an internet-wide 30-day estimate of exploitation activity, not a forecast for my systems). If they give no fixed versions, use the CVE record https://cveawg.mitre.org/api/cve/CVE-2017-6018 or the vendor advisory, not third-party mirrors. Tell me how to check whether I am affected and how to verify a fix. Cite the sources and say where they are uncertain.

Opens a third-party assistant; its answer is its own, not cve.bz's. The prompt holds only this CVE's id and public links.

Affected

ICS advisories (CISA)

AdvisoryTitlePublishedSectorsAffectedFixed
ICSMA-17-082-02ICSMA-17-082-02_B. Braun Medical SpaceCom Open Redirect Vulnerability2017-03-23SpaceStation with SpaceCom module (integrated as part number 8713142U): software versions prior to Version 012U000040, SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U): software versions prior to Version 012U000040none listed

From CISA's ICS advisories (CSAF), provided under CISA's notification. Only the facts are shown; each advisory is on CISA's page. Credits.

Attack patterns (CAPEC)

  • CAPEC-178 Cross-Site Flashing Likelihood: Medium · Severity: Medium

The attack patterns MITRE's CAPEC relates to this record's weaknesses, as MITRE names them. Credits.

References

Check your stackJSON